top of page

Inrush Current Limiting Techniques

  • Writer: Tyler Sangster
    Tyler Sangster
  • Mar 6, 2023
  • 7 min read

Understanding Inrush Current and Its Impact on Electrical Systems

Inrush current represents one of the most significant challenges in electrical and electronics engineering, particularly in industrial applications across Atlantic Canada where harsh environmental conditions and aging infrastructure demand robust design solutions. When electrical equipment is first energized, the initial current draw can exceed normal operating current by factors of 10 to 100 times, creating stress on components, tripping protective devices, and potentially causing system-wide disturbances.

For industries throughout Nova Scotia and the Maritime provinces—from fish processing plants in Lunenburg to manufacturing facilities in the Halifax Regional Municipality—understanding and mitigating inrush current is essential for maintaining reliable operations and protecting valuable equipment investments.

This comprehensive guide explores the fundamental principles of inrush current, examines various limiting techniques, and provides practical guidance for selecting appropriate solutions for your specific applications.

The Physics Behind Inrush Current

Inrush current occurs due to several physical phenomena, depending on the type of equipment being energized. Understanding these mechanisms is crucial for selecting the most effective limiting technique.

Transformer Magnetising Inrush

When a transformer is energized, the magnetic core must establish its operating flux. If the voltage is applied at a zero-crossing point when residual flux opposes the required direction, the core can saturate, drawing currents up to 8 to 12 times the rated full-load current. This magnetising inrush can persist for several cycles to several seconds, depending on transformer size and core material properties.

Capacitor Charging Current

Capacitive loads, including power factor correction banks and switch-mode power supplies, present a near short-circuit condition at the moment of energization. The charging current is limited only by source impedance and any series resistance, potentially reaching 20 to 50 times nominal operating current for brief periods measured in microseconds to milliseconds.

Motor Starting Current

Induction motors draw locked-rotor current until sufficient speed is achieved to generate back-EMF. Typical starting currents range from 6 to 8 times full-load amperage for standard motors, with the duration depending on motor size, load inertia, and supply voltage.

Lamp Filament Cold Resistance

Incandescent and halogen lamps exhibit cold filament resistance approximately 10 to 15 times lower than hot operating resistance, creating significant inrush when lighting circuits are energized—a consideration still relevant for industrial and marine applications common in the Maritimes.

Passive Inrush Current Limiting Techniques

Passive techniques offer simplicity and reliability without requiring external power or complex control systems. These solutions are particularly attractive for remote installations throughout Nova Scotia where maintenance access may be limited.

Series Resistance Limiting

The simplest approach involves placing a resistor in series with the load during startup. The resistance value is calculated using Ohm's law to limit peak current to acceptable levels:

  • Advantages: Low cost, extreme simplicity, no active components to fail

  • Disadvantages: Continuous power dissipation, reduced efficiency, requires bypass mechanism for normal operation

  • Typical applications: Small power supplies under 100W, LED driver circuits, low-power industrial controls

For a 120VAC supply requiring inrush limitation to 10A peak, a series resistance of approximately 12 to 17 ohms would be required, with power rating calculated for worst-case continuous operation plus appropriate safety margin.

Negative Temperature Coefficient (NTC) Thermistors

NTC thermistors provide an elegant self-regulating solution. At ambient temperature, the thermistor presents high resistance (typically 5 to 50 ohms), limiting inrush current. As current flows, self-heating reduces the resistance to minimal levels (often below 1 ohm), restoring near-normal circuit operation.

  • Cold resistance: Selected based on maximum allowable inrush and supply voltage

  • Steady-state resistance: Determines ongoing power dissipation and efficiency impact

  • Thermal time constant: Affects response to repeated switching cycles

  • Maximum current rating: Must exceed steady-state load current with margin

A critical consideration for Maritime applications is the ambient temperature range. NTC thermistors specified for indoor use may not provide adequate protection during cold startups in unheated facilities or outdoor enclosures experiencing Nova Scotia winter temperatures reaching -25°C or below.

Inductors and Chokes

Series inductance limits the rate of current rise (di/dt), providing inherent inrush protection. Saturable reactors and iron-core inductors are commonly employed in medium-power applications.

For capacitive loads, the series inductance required can be calculated based on the desired current limit and rise time. A typical specification might call for 100 to 500 microhenries for switch-mode power supply applications, with saturation current ratings exceeding maximum load current by 50% or more.

Active Inrush Current Limiting Techniques

Active techniques offer superior performance and flexibility, particularly for high-power applications and situations requiring precise control over the energization process.

Pre-Charge Circuits

Pre-charge systems use a combination of series resistance and bypass contactors to limit inrush while maintaining high efficiency during normal operation. The sequence typically involves:

  • Phase 1: Initial energization through current-limiting resistor

  • Phase 2: Monitoring of voltage or current to detect completion of charging/magnetization

  • Phase 3: Bypass contactor closure to remove resistor from circuit

  • Phase 4: Normal operation with minimal series impedance

Pre-charge circuits are standard in electric vehicle battery systems, large capacitor banks, and industrial motor drives. Design considerations include resistor power rating for worst-case pre-charge duration, contactor sizing for bypass current plus margin, and control system timing to prevent premature bypass.

Phase-Controlled Soft Starters

Thyristor-based soft starters gradually increase the applied voltage by controlling the conduction angle over multiple AC cycles. This technique is particularly effective for motor starting applications prevalent in industrial facilities throughout Atlantic Canada.

Modern soft starters offer programmable ramp times (typically 1 to 60 seconds), current limit settings, and integrated protection features. For a 100HP motor with locked-rotor current of 600A, a soft starter can limit starting current to 200 to 350A while extending acceleration time to reduce mechanical stress.

Semiconductor-Based Current Limiters

Linear regulators and current-limiting circuits using MOSFETs or IGBTs provide precise control over inrush current magnitude. These solutions offer:

  • Programmable current limits: Adjustable from milliamperes to hundreds of amperes

  • Fast response: Microsecond-scale reaction to overcurrent conditions

  • Diagnostic capabilities: Integration with monitoring systems for fault detection

  • Thermal protection: Automatic derating or shutdown for overtemperature conditions

The semiconductor device must be selected with adequate safe operating area (SOA) for the worst-case combination of voltage, current, and time during the inrush event. Heat sink design becomes critical, particularly for applications in equipment enclosures with limited airflow.

Application-Specific Considerations for Maritime Industries

The unique operating environment of Atlantic Canada presents specific challenges that must be addressed in inrush current limiting system design.

Marine and Offshore Applications

Vessels operating from ports in Halifax, Yarmouth, and throughout Nova Scotia's extensive coastline require inrush limiting solutions that withstand saltwater exposure, vibration, and wide temperature variations. Marine-grade components with conformal coating, stainless steel hardware, and enhanced environmental sealing are essential.

Generator-fed shipboard power systems are particularly sensitive to inrush events due to limited fault current capacity compared to grid-connected installations. A 50kW shipboard generator may only supply 150 to 200% of rated current during fault conditions, necessitating aggressive inrush limiting to prevent generator overload and voltage collapse.

Renewable Energy Integration

Nova Scotia's expanding renewable energy sector, including wind farms in the Chignecto Isthmus region and tidal power installations in the Bay of Fundy, requires careful attention to inrush current management. Grid-tie inverters, transformer energization, and capacitor bank switching must be coordinated to prevent adverse impacts on grid stability.

Cold Weather Operation

Winter temperatures significantly affect inrush current magnitude and duration. Transformer oil viscosity increases, extending magnetising inrush duration. Motor bearings exhibit higher friction, prolonging acceleration time and increasing thermal stress during starting. Capacitor ESR (equivalent series resistance) may decrease, allowing higher peak charging currents.

Design engineers must analyse worst-case combinations of temperature, voltage, and load conditions to ensure adequate protection margin throughout the operating envelope.

Selection Criteria and Design Methodology

Selecting the optimal inrush current limiting technique requires systematic evaluation of multiple factors:

Electrical Parameters

  • Supply voltage: AC or DC, nominal value, and expected variation range

  • Load characteristics: Resistive, capacitive, inductive, or complex impedance

  • Maximum allowable inrush: Based on protective device ratings and source capacity

  • Steady-state current: Determines bypass requirements and efficiency impact

  • Switching frequency: Affects thermal design for repetitive cycling applications

Environmental and Reliability Factors

  • Operating temperature range: Critical for NTC thermistor and semiconductor selection

  • Humidity and contamination: Affects component selection and enclosure design

  • Service life requirements: Electromechanical vs. solid-state reliability trade-offs

  • Maintenance accessibility: Particularly relevant for remote installations

Economic Considerations

Total cost of ownership analysis should include initial component cost, installation labour, efficiency losses over operating life, and expected maintenance requirements. A simple NTC thermistor solution costing under $5 in components may be appropriate for consumer electronics, while a $5,000 to $15,000 solid-state soft starter investment is easily justified for a critical industrial motor where downtime costs exceed $10,000 per hour.

Testing and Validation

Proper validation of inrush current limiting effectiveness requires appropriate test equipment and methodology:

  • Current measurement: High-bandwidth current probes capable of capturing fast transients (minimum 1MHz bandwidth for most applications)

  • Oscilloscope: Storage capability to capture single-shot events with adequate sample rate

  • Variable AC source: For testing at different phase angles and voltage levels

  • Temperature chamber: For validating performance across the specified operating range

Test procedures should include multiple energization cycles at various initial conditions, with particular attention to hot restart scenarios where components may not have returned to ambient temperature.

Partner with Sangster Engineering Ltd. for Your Inrush Current Challenges

Designing effective inrush current limiting solutions requires careful analysis of electrical, thermal, and environmental factors combined with practical experience across diverse applications. At Sangster Engineering Ltd. in Amherst, Nova Scotia, our team brings decades of experience in electronics engineering and power systems design to every project.

Whether you're developing new industrial equipment, upgrading existing installations, or troubleshooting nuisance protective device tripping, we provide comprehensive engineering services tailored to the unique requirements of Atlantic Canadian industries. Our capabilities include circuit design and simulation, prototype development, thermal analysis, and complete documentation packages meeting Canadian Standards Association (CSA) and other applicable requirements.

Contact Sangster Engineering Ltd. today to discuss your inrush current limiting requirements and discover how our engineering expertise can help ensure reliable, efficient operation of your electrical and electronic systems throughout their service life.

Partner with Sangster Engineering

At Sangster Engineering Ltd. in Amherst, Nova Scotia, we bring decades of engineering experience to every project. Serving clients across Atlantic Canada and beyond.

Contact us today to discuss your engineering needs.

Recent Posts

See All
Power Integrity in PCB Design

Learn essential power integrity techniques for PCB design. Discover how to minimize noise, optimize decoupling, and ensure stable power delivery for reliable circuits.

 
 
 

Comments


Sangster Engineering

©2023 by Sangster Engineering 

bottom of page