Control Panel Design and Layout

  • Writer: Tyler Sangster
    Tyler Sangster
  • Jun 30, 2025
  • 8 min read

Understanding the Fundamentals of Control Panel Design

Control panel design represents one of the most critical aspects of industrial automation, serving as the nerve centre for manufacturing processes, building systems, and industrial equipment throughout Nova Scotia and the broader Atlantic Canada region. A well-designed control panel does more than house electrical components—it ensures operational reliability, facilitates maintenance, promotes safety, and provides a foundation for future system expansion.

For industries across the Maritimes, from food processing facilities in the Annapolis Valley to manufacturing plants in the Halifax Regional Municipality, control panel design must account for unique regional considerations including temperature fluctuations, humidity levels near coastal areas, and compliance with both Canadian Electrical Code (CEC) requirements and provincial regulations administered by Nova Scotia's Technical Safety Division.

The process of designing an effective control panel layout requires careful consideration of electrical load calculations, heat dissipation requirements, wire routing efficiency, and operator accessibility. Whether you're upgrading legacy systems in an established facility or implementing new automation solutions, understanding these fundamental principles will help ensure your investment delivers long-term value and operational excellence.

Key Standards and Regulatory Compliance in Canada

Control panel design in Canada must adhere to a comprehensive framework of standards that ensure safety, reliability, and interoperability. Understanding these requirements is essential for any engineering project in Nova Scotia and throughout the Atlantic provinces.

Canadian Electrical Code Requirements

The Canadian Electrical Code (CEC), published by the Canadian Standards Association (CSA), forms the foundation of all electrical installation requirements. Section 46 specifically addresses emergency power supplies, while various other sections address wire sizing, overcurrent protection, and grounding requirements that directly impact control panel design. In Nova Scotia, the CEC is adopted under the Electrical Installation and Inspection Act, with enforcement handled by licensed electrical inspectors.

CSA and UL Standards for Industrial Control Panels

Industrial control panels typically require certification to CSA C22.2 No. 286, which harmonises with UL 508A for industrial control panels. Key requirements include:

  • Short circuit current rating (SCCR) calculations to ensure the panel can withstand available fault currents, typically ranging from 5,000 to 200,000 amperes depending on installation location

  • Enclosure ratings appropriate for the installation environment, with NEMA Type 4X or IP66 commonly specified for washdown areas in Maritime food processing facilities

  • Component spacing requirements that ensure adequate clearances for voltage levels, typically 25mm minimum for circuits up to 300V

  • Wire bending space calculations based on conductor sizes, with minimum depths specified in CEC Table 36

  • Proper marking and labelling including voltage warnings, SCCR ratings, and equipment identification

Arc Flash Considerations

CSA Z462, Workplace Electrical Safety, mandates arc flash hazard assessments for electrical equipment. Control panel designers must consider incident energy levels and specify appropriate personal protective equipment (PPE) categories. Proper design techniques such as current-limiting fuses, zone-selective interlocking, and arc-resistant enclosures can significantly reduce arc flash hazards, improving worker safety at Nova Scotia industrial facilities.

Thermal Management and Heat Dissipation Strategies

Effective thermal management represents one of the most challenging aspects of control panel design, particularly in Atlantic Canada where seasonal temperature variations can exceed 50°C between winter lows and summer highs inside non-climate-controlled industrial buildings.

Calculating Heat Load

Every component within a control panel generates heat during operation. Accurate heat load calculations must account for:

  • Variable frequency drives (VFDs) typically dissipate 3-5% of their rated power as heat, meaning a 75 kW drive may generate 2,250-3,750 watts of thermal energy

  • Programmable logic controllers (PLCs) and I/O modules generate 5-15 watts per module depending on configuration

  • Power supplies operate at 85-95% efficiency, with the remaining energy converted to heat

  • Contactors and relays produce heat through coil energisation and contact resistance

  • Wire and busbar losses calculated using I²R formulas based on current flow and conductor resistance

Cooling Solutions for Maritime Climates

The selection of appropriate cooling methods depends on ambient conditions, heat load, and enclosure ratings. Common approaches include:

Natural convection relies on louvred vents and the natural tendency of hot air to rise. This method works effectively for panels with heat loads below 50 watts per square metre of panel surface area, provided the ambient temperature remains below 30°C.

Forced air cooling using filtered fans can increase heat dissipation capacity by 300-400%. For Nova Scotia installations, filter maintenance schedules must account for seasonal variations—more frequent changes during spring pollen season and autumn when leaves and debris are prevalent.

Air-to-air heat exchangers provide closed-loop cooling that maintains enclosure integrity while rejecting heat to the surrounding environment. These units are particularly valuable in dusty environments like lumber mills common throughout Nova Scotia's forestry sector.

Enclosure air conditioners offer precise temperature control for critical applications, maintaining internal temperatures at 35°C regardless of ambient conditions. While more expensive to purchase and operate, these units protect sensitive electronics and extend component lifespan significantly.

Component Layout and Wire Routing Best Practices

Strategic component placement and wire routing directly impact panel functionality, maintenance accessibility, and electromagnetic compatibility. Following established best practices ensures optimal performance throughout the panel's operational life.

Vertical Zoning Principles

Professional control panel layout typically follows a vertical zoning approach that separates components by function and heat sensitivity:

  • Upper zone: Heat-generating components such as VFDs, soft starters, and power supplies, allowing heat to rise and exit through top-mounted ventilation

  • Middle zone: Control components including PLCs, I/O modules, and communication equipment, positioned at optimal viewing and access height (1,200-1,500mm from floor)

  • Lower zone: Terminal blocks, fuses, and circuit breakers, providing easy access for field wiring connections

Separation of Power and Control Circuits

Electromagnetic interference (EMI) can cause erratic PLC behaviour, communication errors, and instrumentation inaccuracies. Proper separation techniques include:

Maintaining minimum 150mm spacing between power conductors (especially VFD output cables) and low-voltage control wiring. When crossings are unavoidable, arrange them at 90-degree angles to minimise coupling.

Using separate wireways for power and control circuits, with metallic barriers providing additional shielding. Colour-coded wire duct (grey for control, orange for power) helps maintain separation during installation and future modifications.

Routing shielded cables for analog signals, with shields grounded at one end only (typically at the control panel) to prevent ground loops that cause measurement errors in instrumentation circuits.

Maintenance Accessibility Requirements

Control panels in Nova Scotia industrial facilities may operate for 20-30 years, requiring numerous maintenance interventions over their lifespan. Design considerations should include:

  • Minimum 200mm clearance between components for hand access during troubleshooting

  • Hinged sub-panels providing access to components mounted on the enclosure rear

  • Adequate terminal block sizing with 20-30% spare capacity for future expansion

  • Clear labelling of all components, terminals, and wires using permanent marking methods

  • Test points strategically located for voltage verification without removing covers

Human-Machine Interface Design and Operator Considerations

The operator interface represents the primary interaction point between human workers and automated systems. Thoughtful HMI design improves operational efficiency, reduces errors, and enhances safety across Maritime industrial operations.

Ergonomic Placement Standards

CSA Z1004, Workplace Ergonomics, provides guidance for control station design. Key considerations include:

Primary displays and frequently used controls should be positioned within the optimal viewing zone, typically 15 degrees below horizontal eye level at a distance of 500-700mm. For standing operators, this translates to mounting heights of 1,400-1,600mm from floor level.

Emergency stop buttons must be readily accessible, positioned 800-1,200mm from floor level and within 1 metre horizontal reach from the normal operating position. Red mushroom-head buttons with yellow backgrounds provide maximum visibility as required by CSA Z432.

Display and Indicator Design

Effective visual communication requires attention to colour coding, sizing, and positioning:

  • Green indicators represent normal, safe, or running conditions

  • Red indicators signal alarms, faults, or emergency conditions

  • Amber/yellow indicators warn of abnormal conditions requiring attention

  • Blue indicators designate permissive or informational status

  • White indicators show non-critical process information

Minimum indicator lamp size of 22mm diameter ensures visibility at distances up to 5 metres under typical industrial lighting conditions of 300-500 lux.

Touchscreen HMI Considerations

Modern control panels increasingly incorporate touchscreen HMIs ranging from 7-inch local displays to 21-inch supervisory stations. Design factors specific to Maritime industrial environments include:

Selecting resistive or projected capacitive touchscreens rated for operation with gloves, essential for Nova Scotia facilities where workers may wear protection against cold temperatures or process chemicals.

Specifying high-brightness displays (minimum 400 cd/m²) with anti-glare coatings to maintain readability under the bright lighting common in food processing and pharmaceutical cleanrooms.

Documentation and Quality Assurance

Comprehensive documentation ensures control panels can be properly installed, commissioned, operated, and maintained throughout their service life. Quality assurance processes verify that finished panels meet design specifications and regulatory requirements.

Essential Documentation Package

A complete control panel documentation package should include:

  • Electrical schematics showing all circuits, with wire numbers corresponding to physical labels

  • Panel layout drawings indicating component positions and dimensions

  • Bill of materials listing all components with manufacturer part numbers and Canadian suppliers

  • SCCR calculations demonstrating compliance with available fault currents

  • Heat load analysis and cooling system specifications

  • PLC and HMI programme documentation including ladder logic printouts and screen captures

  • I/O lists correlating field devices to PLC addresses

  • Test reports documenting point-to-point verification and functional testing

Factory Acceptance Testing

Factory acceptance testing (FAT) at the panel builder's facility allows identification and correction of issues before shipment. Standard FAT procedures include:

Visual inspection verifying proper component installation, wire routing, and labelling. Dimensional verification confirms the panel will fit the designated installation location.

Electrical testing including insulation resistance measurements (minimum 1 megohm at 500VDC for low-voltage circuits), continuity verification of all control circuits, and protective device operation testing.

Functional testing that simulates normal and abnormal operating conditions, verifying proper PLC programme execution, HMI display accuracy, and alarm functionality.

Future-Proofing Your Control Panel Investment

Control panels represent significant capital investments that should deliver reliable service for decades. Forward-thinking design decisions ensure panels can adapt to evolving operational requirements and technological advances.

Expansion Capacity Planning

Industry best practice recommends reserving 20-30% spare capacity in all aspects of control panel design:

  • Physical space for additional components, with pre-punched mounting holes or DIN rail provisions

  • Electrical capacity in power supplies, transformers, and distribution equipment

  • PLC I/O points including spare module slots and terminal capacity

  • Communication ports and network switch capacity for future device integration

  • Wire duct fill limited to 40-50% to accommodate future additions

Industrial Internet of Things Readiness

Atlantic Canadian industries are increasingly adopting Industrial Internet of Things (IIoT) technologies for remote monitoring, predictive maintenance, and operational optimisation. Control panel designs should accommodate these capabilities through:

Ethernet-based communication infrastructure using industrial-grade managed switches with appropriate cybersecurity features. The latest generation of PLCs and drives offer built-in connectivity options that can be enabled as needs evolve.

Edge computing provisions allowing local data processing and analytics without requiring constant cloud connectivity—particularly valuable in rural Nova Scotia locations where internet reliability may be limited.

Partner with Atlantic Canada's Automation Experts

Effective control panel design requires deep expertise in electrical engineering, automation systems, and regional regulatory requirements. From initial concept through commissioning and ongoing support, professional engineering guidance ensures your control systems deliver reliable, safe, and efficient operation.

Sangster Engineering Ltd. brings decades of experience to control panel design and automation projects throughout Nova Scotia and the Maritime provinces. Our team understands the unique challenges facing Atlantic Canadian industries, from harsh coastal environments to the specific requirements of regional sectors including food processing, manufacturing, and natural resources.

Whether you're planning a new facility, upgrading existing control systems, or seeking to improve operational efficiency through automation, contact Sangster Engineering Ltd. in Amherst, Nova Scotia to discuss how our professional engineering services can support your project objectives. Our comprehensive approach to control panel design ensures compliance with all applicable codes and standards while delivering practical solutions that meet your operational needs and budget requirements.

Partner with Sangster Engineering

At Sangster Engineering Ltd. in Amherst, Nova Scotia, we bring decades of engineering experience to every project. Serving clients across Atlantic Canada and beyond.

Contact us today to discuss your engineering needs.

Recent Posts

See All
Collaborative Robot Safety Standards

Discover essential collaborative robot safety standards, compliance requirements, and best practices to ensure safe human-robot interaction in your automated workplace.

 
 
 
Predictive Maintenance System Design

Discover how to design effective predictive maintenance systems for automation. Learn key components, sensors, data analytics, and implementation strategies.

 
 
 
SCADA System Architecture Design

Discover essential SCADA system architecture design principles, components, and best practices for building reliable, secure industrial automation networks.

 
 
 

Comments


Sangster Engineering

©2023 by Sangster Engineering 

bottom of page